The Problem in One Sentence

If you stop the draughts, you also stop the routes by which moisture used to leave the house. That is the core of Roger Bisby’s argument on the Skill Builder channel, and it is one every retrofit professional should be able to explain to a client.

Bisby describes a pattern that turns up again and again in his inbox: homeowners replace rattly sash windows with sealed, draught-proofed PVC units, fit a new door, and then find mould that keeps coming back however often they clean it off. In his words, the problem has reached “epidemic proportions”.

Remember: Draughts were never a ventilation strategy, but in many older homes they were doing the job of one. Remove them and something deliberate has to take their place.

Why Sealing Up Causes Mould

Everyday living produces moisture: cooking, showering, breathing, and drying washing indoors. In a leaky house that airborne moisture escapes through gaps around windows, doors, and floors. In a sealed house it stays, the relative humidity rises, and it condenses on the coldest surfaces.

Bisby calls the push for airtightness without a matching requirement for mechanical ventilation “a bad experiment”. Whether or not you agree with the framing, the building physics is sound, and it is the reason PAS 2035 treats ventilation as part of the retrofit rather than an optional extra. The existing ventilation must be assessed, and where it will not be adequate for the improved dwelling it has to be upgraded alongside the fabric work.

For a fuller treatment of the moisture mechanisms, see our complete guide to damp, mould and condensation.

The Ventilation Options Covered

The video runs through the main ways of putting controlled ventilation back into a sealed home.

OptionHow it worksPoints to note
MVHR (mechanical ventilation with heat recovery)Extracts stale air, supplies fresh air, and recovers part of the heatWhole-house or single-room units; it cannot recover 100% of the heat
Positive input ventilation (PIV)A loft-mounted fan supplies filtered, slightly warmed air and puts the house under gentle pressureNeeds open trickle vents or other escape paths; Bisby puts running costs at around £60 a year
Humidity-sensing extract fansRun quietly at a low rate and boost when humidity risesLow running cost; deals with moisture at source in kitchens and bathrooms
DehumidifierRemoves moisture from the air in one roomGood for drying washing; does not supply fresh air
Purge ventilationWindows opened wide for about a quarter of an hourFree, but depends entirely on the occupant

Tip: PIV works by pushing moist air out, so it needs somewhere for that air to go. With the trickle vents taped over, the system has no exit path.

PIV is widely used as a remedial measure for mould, but it should not be assumed to satisfy a retrofit ventilation design. Check it against the project’s ventilation strategy and the applicable guidance before specifying it. Our post on retrofit ventilation systems that fit existing homes looks at alternatives that are easier to install in occupied houses.

Occupants Are Part of the System

Bisby is careful not to blame tenants alone, but he lists behaviours that landlords report regularly:

  • Pulling the fuse out of the extractor fan
  • Keeping trickle vents closed, or taping over them
  • Drying washing on radiators
  • Never opening windows in winter

The motive is nearly always the same: people are worried about cold draughts and heating bills. That matters for retrofit professionals because a ventilation system that occupants disable is not working, however well it was specified.

This is where the PAS 2035 emphasis on handover and occupant advice earns its place. Explain what each fan does, what it costs to run, and why the trickle vents should stay open. A fan that runs quietly and costs pennies is far less likely to be switched off than a noisy one.

Did you know? Bisby recommends hanging washing in a single room with a dehumidifier running. The drier air pulls moisture from the clothes, so the room does not even need to be heated.

What Happens When It Goes Wrong

The most sobering example in the video is a home where a toxicology report recommended disposing of everything in the house: carpets, furniture, and clothes. The reasoning given was that returning contaminated possessions to a cleaned house would reintroduce the mould.

That is an extreme case, but it makes the cost comparison plain. A fan costing tens of pounds a year to run is trivial against the cost of remediation, replacement belongings, and the health effects Bisby describes, including children with asthma.

The Purge Ventilation Routine

For homes with no mechanical system, Bisby suggests a simple routine:

  1. Before the heating comes on, open the windows wide.
  2. Let fresh air blast through for about a quarter of an hour.
  3. Close up and then switch the heating on.

The heating then warms cooler, drier air instead of moist air. Bisby adds that lower humidity makes a home feel warmer. Treat this as a useful habit to recommend to occupants, not as a designed ventilation solution.

What This Means for Each Retrofit Role

RoleWhat to take from this
Retrofit AssessorRecord existing ventilation accurately: fans, trickle vents, undercuts, and any signs of condensation or mould
Retrofit CoordinatorTreat airtightness and ventilation as one risk; make sure the ventilation strategy matches the improved fabric
Retrofit InstallerDo not block or remove ventilation paths during fabric work; report anything that conflicts with the design

If the project includes whole-house mechanical ventilation, our guide to MVHR and ERV grille placement covers where supply and extract terminals should go.

How RetrofitReady Fits Into This

Ventilation and moisture risk run through every retrofit qualification, and exam questions often test exactly the link this video describes: what changes when a home is made more airtight, and who is responsible for dealing with it.

  • RetrofitReady: Coordinator has 600 PAS 2035 questions across domestic retrofit, risk, fabric, services, ventilation, MTIP, and monitoring.
  • Retrofit Assessor has 480 questions across eight syllabus areas, including multi-answer and diagram-based practice.
  • RetrofitReady: Installer has 480 questions across the two core PAS 2030 units and six fabric measures, including multi-answer and diagram-based practice.

Together the RetrofitReady suite offers 1900+ questions across 4 apps. Start with ventilation and moisture as a single topic, read the explanations for every question you miss, and then move on to mixed practice.

Continue with the free quizzes or browse the full RetrofitReady app suite.

FAQ

Why does mould appear after new windows or draught-proofing are fitted?

Old windows and doors leaked air, which carried moisture out of the home. Sealing those gaps without adding purpose-provided ventilation traps airborne moisture, which then condenses on cold surfaces and feeds mould.

Does PAS 2035 require ventilation to be upgraded when a home is made more airtight?

PAS 2035 requires the existing ventilation to be assessed and, where it is inadequate for the improved dwelling, upgraded as part of the retrofit design. Fabric and airtightness measures should not be treated separately from ventilation.

What is the difference between MVHR and positive input ventilation?

MVHR extracts stale air and supplies fresh air, passing the two through a heat exchanger so that part of the heat is recovered. Positive input ventilation supplies filtered air, usually from the loft, to put the home under slight positive pressure and push moist air out through trickle vents and gaps.

Is a dehumidifier a substitute for ventilation?

No. A dehumidifier is a useful way to deal with a specific moisture source, such as drying washing in one room, but it does not provide fresh air. It supports a ventilation strategy and does not replace one.

Which RetrofitReady app covers ventilation and moisture risk?

All three retrofit apps cover it from the angle of the role: Retrofit Assessor for recording existing ventilation and condition, RetrofitReady: Coordinator for risk and ventilation strategy, and RetrofitReady: Installer for getting fabric measures right on site.

Related Apps

Retrofit Assessor icon
Assessor

Retrofit Assessor

PAS 2035 Retrofit Assessor revision with 480 questions across eight syllabus areas, including multi-answer and diagram-based practice.

480Questions
8Topics
RetrofitReady: Coordinator icon
Coordinator

RetrofitReady: Coordinator

Level 5 Retrofit Coordinator preparation with 600 PAS 2035 questions across domestic retrofit, risk, fabric, services, ventilation, MTIP, and monitoring.

600Questions
10Topics
RetrofitReady: Installer icon
Installer

RetrofitReady: Installer

PAS 2030 Retrofit Installer revision with 480 questions across the two core units and six fabric measures, including multi-answer and diagram-based practice.

480Questions
8Topics

Continue Practising

Use a free quiz, then continue in the app with the full question bank.

Back to all articles